MIDAS-E-H2X | Honeywell Midas® hydrogen ppm 0–1000 ppm

MIDAS-E-H2X is a Honeywell Midas® 2-year E cartridge for hydrogen ppm (H₂), range 0–1000 ppm, electrochemical. It plugs into the MIDAS-T-004 extractive transmitter — not a Sensepoint XCD diffusion head. Sample line up to 30 m FEP at ~500 mL/min.

MIDAS-E-H2X Honeywell Midas hydrogen ppm

Mechanical & wiring figures

Product view (datasheet)
Product view (datasheet)
Outline dimensions
Outline dimensions
Main chassis
Main chassis
Terminal wiring
Terminal wiring

Расшифровка артикула

СегментЗначениеЭтот артикул
MIDASHoneywell Midas® extractiveMIDAS
E2-year cartridgeE
H2Xhydrogen ppmH2X

Характеристики

CategoryКассета · 2 года
GasH₂ / hydrogen ppm
Range0–1000 ppm
Principleelectrochemical
Flowapprox. 500 mL/min
Sample length2–30 m FEP
Supply24 VDC or PoE 48 V
Outputs0–21 mA + 3 relays + Modbus TCP/PoE
Temperature0–40 °C (0–30 °C with pyrolyzer)
Size / mass150×65×153 mm / 0.8 kg
ApprovalsCE, EN 50270, UL 61010-1, IEEE 802.3af

Transmitter 150×65×153 mm / 0.8 kg; NF₃ pyrolyzer 70×63×85 mm / 0.41 kg; high-temp PFC pyrolyzer 100×101×140 mm / 1.36 kg.

Зачем этот артикул

Midas is extractive: the cell sits in the tool cabinet while FEP pulls sample from the valve box. hydrogen ppm uses electrochemical. Pyrolyzed species need MIDAS-T-00P / T-HTP / T-NP1 or the cartridge will not read.

Совместимость и ЗИП

MIDAS-E-H2X mates to MIDAS-T-004. Pump MIDAS-A-007, internal filter MIDAS-A-009. Same-gas 1-year S cartridge is the short-warranty sibling. Calibration notes live on product-2679.

Типовые применения

Gas cabinets, VMBs, wet benches and CVD/etch exhaust. MIDAS-E-H2X locks gas and cartridge life; budget transmitter, pump A-007 and internal filter A-009 on the PM cycle.

Сравнение

P/NTypeGasRange
MIDAS-S-H2XКассета · 1 годH₂0–1000 ppm
MIDAS-T-004Экстрактивный преобразовательMIDAS-T-004
MIDAS-A-007ЗИПMIDAS-A-007
MIDAS-E-ASHКассета · 2 годаAsH₃/GeH₄AsH₃ 0–200 ppb / GeH₄ 0–800 ppb
MIDAS-E-B2HКассета · 2 годаB₂H₆0–400 ppb
MIDAS-E-BR2Кассета · 2 годаBr₂/ClO₂0–0.4 ppm
MIDAS-E-CFHКассета · 2 годаPFCppm PFC

Матрица семейства Midas

Монтаж и линия отбора

Wall-mount MIDAS-T-004 on the pre-drilled chassis or DIN kit A-036, then insert MIDAS-E-H2X. Sample 1/8″ID×1/4″OD FEP to 30 m; exhaust 1/4″ID×3/8″OD to 30 m. End-of-line filter 0780248 or 1830-0055/0027 by gas. 24 VDC (−15%/+10%) or PoE 48 V; pyrolyzer load up to 12.95 W. 0–40 °C, 0–30 °C with pyrolyzer.

FAQ

Can MIDAS-E-H2X plug into Sensepoint XCD?
No. Midas is an extractive cartridge; XCD is a diffusion sensor housing. They do not mate.
Does MIDAS-E-H2X need a pyrolyzer?
Gases marked ** (CH₂F₂, C₄F₆, C₅F₈, NF₃, CH₃F) need MIDAS-T-00P / T-HTP / T-NP1 plus a ventilated cover.
MIDAS-E-H2X vs the S cartridge?
Same gas and range. E is 2-year extended warranty; S is 1-year. LEL cartridges warrant 2 years but can be calibrated to 5.
How is 4–20 mA landed on MIDAS-E-H2X?
3-wire sink, 3-wire source or 4-wire isolated 0–21 mA; plus 3 relays and Modbus TCP / PoE. Max 14 AWG.